Implantable Pressure Sensor Encapsulation for Ventricular Assist Device Control


Menge:  Stück  
Produktinformationen
cover
cover
Artikel-Nr.:
     5667A-9783866288348
Hersteller:
     Hartung-Gorre
Herst.-Nr.:
     9783866288348
EAN/GTIN:
     9783866288348
Suchbegriffe:
Medizinbücher
Medizinbücher - englischsprachig
Autonomous feedback controlled ventricular assists device (VAD) operation promises a plethora of benefits such as increased patient safety, comfort, and reduced healthcare costs. Current generation VADs operate at static pump speeds due to the lack of available biocompatible, long-term stable pressure sensor systems. In this thesis, a pressure sensor encapsulation was developed and integrated in an inflow cannula for a VAD and in an implantable testing platform for animal trials. The encapsulation uses a media separating diaphragm embedded in a Parylene C coating. The approach is expanded to enable optimized diaphragm shapes, which allow significantly better control over the final device characteristics, especially the temperature cross sensitivity. Furthermore, a production processes was developed to minimize assembly induced internal overpressure. The produced capsules showed excellent pressure transmission of more than 99.7 % and a temperature cross sensitivity of less than 266 Pa from 35 °C to 42 °C for most capsules. However, a large temperature cross sensitivity was observed from room to body temperature in some capsules, adding relevant drift of 750 Pa (75 % quartile) after 42 days to the measurement. The observed drift is related to the viscoelastic nature of the Parylene C diaphragm and the capsule-to-capsule variation is attributed to production process variations, which can be further optimized. Systematic errors in the pressure transmission, temperature cross sensitivity (TCS), and drift were extracted and correction approaches for each were developed. This enabled the reduction of the pressure transmission error by 50 % by linear correction. A differential measurement approach reduced the temperature cross sensitivity to less than 70 Pa from 35 °C to 42 °C and drastically reduced the temperature induced drift to 300 Pa (75 % quartile) after a jump from room to body temperature. Half of all sensors even remained within a +- 100 Pa window in the same time period.An alternative drift correction solution was developed based on the Burgers model for viscoelastic materials. This approach performed almost as well as the differential correction, but with the added benefit of being applicable to single sensor systems. One of the implantable testing platforms was used in three acute animal trials. It matched the systolic and diastolic pressures recorded by a catheter tip sensor within a +- 133 Pa window for most measurements. The developed solutions and gained understanding with the proof of concept device build a solid foundation for future pressure sensor integrations for VAD applications.
Weitere Informationen:
Author:
Matthias Alexander Dupuch; Christofer Hierold
Verlag:
Hartung-Gorre
Sprache:
eng
Weitere Suchbegriffe: Parylene; Ventricular Assist Device (VAD); blood pressure monitoring; blood pressure sensor; sensor encapsulation, Implantable Pressure Sensor, Encapsulation, Ventricular Assist Device Control
Die Konditionen im Überblick1
Lieferzeit
Lagerstand
Preis
€ 58,18*
Konditionen selbst auswählen
Artikel empfehlenArtikel merken
* Preise mit Sternchen sind Nettopreise zzgl. gesetzlich gültiger MwSt.
UVP bedeutet „Unverbindliche Preisempfehlung“
Unser Angebot richtet sich ausschließlich an Unternehmen, Gewerbetreibende und Freiberufler.